Go to: Content » | Main menu » | Information menu »


Secondary menu

RTL - Three phase cast resin line inductor

For harmonic filtering. Line voltage 380 - 460 V.

Series: 
RTL
RTL - Three phase cast resin line inductor
If you need more information you can contact us. If you are not logged in you can log in here
  • Advantages of cast resin technique:
    • Protection against corrosive environments
    • Suitable for elevated vibration levels
    • No damange of wire isolation due to current peaks
    • Reduction of noise and internal vibrations

Products in this family

Reference Description In (A) Rating motor L (mH)
RTL2.5 RTL - three phase cast resin line inductor 2,5 A 0,75 kW / 1 CV 11,762
RTL4 RTL - three phase cast resin line inductor 4 A 1,1 kW / 1,5 CV 7,351
RTL5 RTL - three phase cast resin line inductor 5 A 1,5 kW / 2 CV 5,881
RTL6.3 RTL - three phase cast resin line inductor 6,3 A 2,2 kW / 3 CV 4,667
RTL8 RTL - three phase cast resin line inductor 8 A 3 kW / 4 CV 3,676
RTL10 RTL - three phase cast resin line inductor 10 A 4 kW / 5,5 CV 2,941
RTL12.5 RTL - three phase cast resin line inductor 12,5 A 5,5 kW / 7,5 CV 2,352
RTL16 RTL - three phase cast resin line inductor 16 A 6,5 kW / 8,7 CV 1,838
RTL20 RTL - three phase cast resin line inductor 20 A 7,5 kW / 10 CV 1,470
RTL25 RTL - three phase cast resin line inductor 25 A 11 kW / 15 CV 1,176
RTL31.5 RTL - three phase cast resin line inductor 31,5 A 15 kW / 20 CV 0,933
RTL40 RTL - three phase cast resin line inductor 40 A 18,5 kW / 25 CV 0,735
RTL50 RTL - three phase cast resin line inductor 50 A 22 kW / 30 CV 0,588
RTL63 RTL - three phase cast resin line inductor 63 A 30 kW / 40 CV 0,467
RTL80 RTL - three phase cast resin line inductor 80 A 37 kW / 50 CV 0,368
RTL100 RTL - three phase cast resin line inductor 100 A 45 kW / 60 CV 0,294
RTL125 RTL - three phase cast resin line inductor 125 A 55 kW / 75 CV 0,235

Dimensions and weights

Reference In (A) Dimensions mm Weight kg Fig
A B C D E Ø
RTL2.5 2,5 A 135 145 108 125 102 7 1.5 1
RTL4 4 A 135 145 108 125 102 7 1.7 1
RTL5 5 A 135 145 108 125 102 7 2 1
RTL6.3 6,3 A 135 145 108 125 102 7 2.5 1
RTL8 8 A 135 145 108 125 102 7 2.7 1
RTL10 10 A 170 165 138 145 125 7 3.4 1
RTL12.5 12,5 A 170 165 138 145 125 7 3.9 1
RTL16 16 A 170 165 138 145 125 7 5.3 1
RTL20 20 A 210 198 185 178 173 7 6 1
RTL25 25 A 210 198 185 178 173 7 7.5 1
RTL31.5 31,5 A 210 198 185 178 173 7 9.7 1
RTL40 40 A 210 198 185 178 173 7 10.2 1
RTL50 50 A 280 190 205 80 250 9 13.9 2
RTL63 63 A 280 190 205 100 250 9 16.7 2
RTL80 80 A 280 190 205 115 250 9 20.1 2
RTL100 100 A 280 220 205 110 250 9 24.5 2
RTL125 125 A 340 220 255 106 310 9 30.3 2

Technical characteristics

Isolation Class F - 155ºC
Winding Class HC - 200ºC
Thermal class F
Thermal over load factor 5 %
Frequency 50-60 Hz
Protection degree IP-20
Includes Thermal protection against over temperature
Temperature rise < 90 ºC
Standard IEC/EN/UNE-EN 60076-6, CE
Ambient temperature 40ºC
Line voltage 380 - 460 V
Test voltage 3 kV (1 min, 50 Hz)
  • Drop voltage: 4%
  • Reduction of current harmonics generated by the load, resulting in energy consumption reduction and power factor improvement
  • Reduction of the crest factor of the current wave, extending the lifetime of the equipment and avoiding breakdowns
  • Attenuation of microcuts in the supply voltage generated by power converters, causing malfuntioning of computers, PLC's and other sensitive equipment

Related content

Please register or login to see all documents and information related to this item
Application guide RTL-RTLX
Declaration of Conformity CE (PR-R-RTL-RTLX-RTFX-RTOX)
Harmonic compensators leaflet