Go to: Content » | Main menu » | Information menu »


Secondary menu

TR - Single phase cast resin transformer rectifier unit

Without capacitor filter. Non stabilised DC power supply. Input 230 V.

Series: 
TR
Single phase cast resin transformer rectifier
If you need more information you can contact us. If you are not logged in you can log in here
  • Non stabilised DC power supply
  • Advantages of cast resin technique:
    • Protection against corrosive environments
    • Suitable for elevated vibration levels
    • No damange of wire isolation due to current peaks
    • Reduction of noise and internal vibrations

Products in this family

Reference Description Output current Input voltage Output voltage
TRA1.6 TR - Single phase cast resin transformer rectifier unit 1,6 A DC 230 V 12 V DC
TRA2.5 TR - Single phase cast resin transformer rectifier unit 2,5 A DC 230 V 12 V DC
TRA4 TR - Single phase cast resin transformer rectifier unit 4 A DC 230 V 12 V DC
TRA6.3 TR - Single phase cast resin transformer rectifier unit 6,3 A DC 230 V 12 V DC
TRA10 TR - Single phase cast resin transformer rectifier unit 10 A DC 230 V 12 V DC
TRA16 TR - Single phase cast resin transformer rectifier unit 16 A DC 230 V 12 V DC
TRA25 TR - Single phase cast resin transformer rectifier unit 25 A DC 230 V 12 V DC
TRA40 TR - Single phase cast resin transformer rectifier unit 40 A DC 230 V 12 V DC
TRA63 TR - Single phase cast resin transformer rectifier unit 63 A DC 230 V 12 V DC
TRB1.6 TR - Single phase cast resin transformer rectifier unit 1,6 A DC 230 V 24 V DC
TRB2.5 TR - Single phase cast resin transformer rectifier unit 2,5 A DC 230 V 24 V DC
TRB4 TR - Single phase cast resin transformer rectifier unit 4 A DC 230 V 24 V DC
TRB6.3 TR - Single phase cast resin transformer rectifier unit 6,3 A DC 230 V 24 V DC
TRB10 TR - Single phase cast resin transformer rectifier unit 10 A DC 230 V 24 V DC
TRB16 TR - Single phase cast resin transformer rectifier unit 16 A DC 230 V 24 V DC
TRB25 TR - Single phase cast resin transformer rectifier unit 25 A DC 230 V 24 V DC
TRB40 TR - Single phase cast resin transformer rectifier unit 40 A DC 230 V 24 V DC
TRB63 TR - Single phase cast resin transformer rectifier unit 63 A DC 230 V 24 V DC
TRC1.6 TR - Single phase cast resin transformer rectifier unit 1,6 A DC 230 V 48 V DC
TRC2.5 TR - Single phase cast resin transformer rectifier unit 2,5 A DC 230 V 48 V DC
TRC4 TR - Single phase cast resin transformer rectifier unit 4 A DC 230 V 48 V DC
TRC6.3 TR - Single phase cast resin transformer rectifier unit 6,3 A DC 230 V 48 V DC
TRC10 TR - Single phase cast resin transformer rectifier unit 10 A DC 230 V 48 V DC
TRC16 TR - Single phase cast resin transformer rectifier unit 16 A DC 230 V 48 V DC
TRC25 TR - Single phase cast resin transformer rectifier unit 25 A DC 230 V 48 V DC
TRC40 TR - Single phase cast resin transformer rectifier unit 40 A DC 230 V 48 V DC
TRC63 TR - Single phase cast resin transformer rectifier unit 63 A DC 230 V 48 V DC

Dimensions and weights

Reference Output current Dimensions mm Weight kg Fig
A B C
TRA1.6 1,6 A DC 80 97 74 0 0 6 0.76 1
TRA2.5 2,5 A DC 80 97 84 0 0 6 0.95 1
TRA4 4 A DC 111 100 99 0 0 6 1.4 1
TRA6.3 6,3 A DC 112 100 122 0 0 6 1.9 1
TRA10 10 A DC 125 102 142 0 0 7 2.9 1
TRA16 16 A DC 137 112 160 0 0 7 4 1
TRA25 25 A DC 149 122 195 0 0 7 6.3 1
TRA40 40 A DC 167 145 227 0 0 7 10 1
TRA63 63 A DC 240 290 200 0 0 7 15 1
TRB1.6 1,6 A DC 95 96 85 0 0 6 1.3 1
TRB2.5 2,5 A DC 95 96 100 0 0 6 1.8 1
TRB4 4 A DC 120 102 124 0 0 6 2.8 1
TRB6.3 6,3 A DC 133 112 128 0 0 6 3.3 1
TRB10 10 A DC 149 122 157 0 0 7 4.9 1
TRB16 16 A DC 167 145 191 0 0 7 7.4 1
TRB25 25 A DC 167 145 237 0 0 7 11.3 1
TRB40 40 A DC 191 165 250 0 0 7 15.8 1
TRB63 63 A DC 240 290 200 0 0 7 27 1
TRC1.6 1,6 A DC 95 96 100 0 0 6 1.8 1
TRC2.5 2,5 A DC 104 102 110 0 0 6 2.7 1
TRC4 4 A DC 132 112 130 0 0 6 3.8 1
TRC6.3 6,3 A DC 145 122 157 0 0 7 5.5 1
TRC10 10 A DC 167 145 199 0 0 7 9.3 1
TRC16 16 A DC 191 165 224 0 0 7 13.6 1
TRC25 25 A DC 191 165 270 0 0 7 17.8 1
TRC40 40 A DC 240 290 200 0 0 7 31.4 1
TRC63 63 A DC 290 340 240 0 0 7 49.4 1

Technical characteristics

Isolation Class B - 130º C
Winding Class HC - 200ºC
Cover Cast resin
Frequency 50-60 Hz
Protection degree
IP-20
Includes Fuse in primary as from 300 W
DIN rail mounting (TR 1,6, TR 2,5 and TRA4)
Standards IEC/EN/UNE-EN 61204 CE
Output ripple
48%
Ambient temperature
25ºC
Test voltage
3 kV (1 min, 50 Hz) between input and output
3 kV (1 min, 50 Hz) between input and earth
0,5 kV (1 min, 50 Hz) between ouput and earth

Related content

Please register or login to see all documents and information related to this item
Declaration of Conformity CE (PTR-TR-TRF-TRT)